LMR400

LMR400
Specifications
ConstructionMaterialsDimensions(mm)
Inner conductor Copper-clad aluminum wire2.74
DielectricFoam PE7.24
First ShieldDouble AL foil bonded7.39
Second Shield144x0.16mm Al Braid (91% coverage, pitch:22.4mm)8.08
JacketBlack PE10.29
Electrical Characteristics
Impedance(Ω)50 ohm
Capacitance78.0 pF/m
dc Resistance, Inner Conductor4.490 ohms/km
dc Resistance, Outer Conductor17.5 ohms/km
dc Test Voltage2500 V
Jacket Spark Test Voltage (rms)4000 V
Maximum Frequency16.20 GHz
Operating Frequency Band30 – 6000 MHz
Peak Power16.0 kW
Shielding Effectiveness>85 dB
Velocity0.85
Installation TemperatureDe -40 °C to +85 °C
Operating TemperatureDe -40 °C to +85 °C
Storage TemperatureDe -70 °C to +85 °C
Mechanical Specifications
Bending Moment0.7 N-m
Flat Plate Crush Strength0.7 kg/mm
Minimum Bend Radius, Single Bend25.40 mm
Tensile Strength73 kg
Attenuation ( @20 ℃ )
Frequency(MHz)Attenuation(dB/100m)Attenuation (dB/100 ft)
302.490.76
503.180.97
1504.921.5
2206.231.9
4508.862.7
90012.83.9
150016.75.1
180018.45.6
200019.45.9
240021.656.6
2500226.7
300024.67.5
Packing
Cable Length :305 m | 1000 ft
Wooden Reel size:457x206x330mm(Flange diameterx Inner tube diameterx Height)